Then test the generator. A pressurewasher, by contrast, typically dispenses water at several thousand PSI, depending upon the model. It is important to consult your owners manual before making any changes to your generator as damage caused by improper service or use of incorrect parts are not covered under warranty. Set the MLCB (generator disconnect) to ON (CLOSED). At the controller, set the generator to OFF. This has the side benefit of being quieter than a rough generator. The continuity test means there is no or low resistance, and this is an indication that the two points are connected. Suppose the carburetor isnt the problem. Set the generator MLCB (generator disconnect) to OFF (OPEN). If you live in a large city, you might have better luck finding a dealer, if not you are on your own. The voltage regulator sends power from the alternator to the battery to keep it charged. Maximum Total Head Lift is how far up (away) the pump can push the water. Take out the spark plugs and inspect them. The system now operates in automatic mode. This is especially true if the fuel tank itself has corroded or cracked, whether due to extremely cold weather or damage from being dropped. On more professional-grade models, the spray is even powerful enough to strip paint, which is useful in paint preparation. Other systems are available to cover virtually any application: Essential Circuit Coverage Generac takes the guesswork out of sizing by offering prepackaged Guardian Series generator systems. Fuel lines are hoses. When power is restored to your home, return to the generator and select Auto on the generator control to restore it to automatic modeWe hope that you found this video informative and helpful. With a few clicks of your mouse you can find the optimal home backup power solution for your needs. What does the magic is the battery of the generator. Keeping up with scheduled maintenance ensures your home standby or portable generator operates in top condition and meets warranty requirements. So, we added an older, separate WiFi for our new generator, which is working well. An automatic backup generator is a back up electrical system that operates whether you are home or away. To be fully productive on the job site, though, you probably need at least 3000 PSI. Together, they provide your pressurewashers cleaning power. You can solve this by cleaning the carburetor with carburetor cleaner. In a partial home application, the transfer switch is installed similarly to a subpanel, and the circuits that are covered by the generator are moved either into a circuited transfer switch, or are installed in a subpanel that is protected by a non-circuited transfer switch. Make sure the gas to your generator is turned on. Happy to be ready! That is why we want to give you as much information as possible so you can make the right decision based on your needs and budget. On top of that, it can be a warning that the generator is about to break down. Keep track of your generator's maintenance schedule to ensure your standby is running smoothly. Please refer to your owner's manual to determine the solution for each problem. Think hard if you really need a generator! That stops the flow of fuel into the carburetor. We have 2 toddlers and it was just really annoying to not have power with little kids. Want to get all the answers to your questions about home backup power all in one place? If youve had to clear clogs from the fuel lines because of bad fuel, make sure the fuel lines are securely connected to the appropriate points. The Generac standby generator will finally be run in a video! Drain the bad fuel, clean it with carburetor cleaner, add fresh fuel and try it. If the switch is defective, it will prevent the generator from starting up. Above 32F, use SAE 30. Get a glimpse into how long your generator has run for during its lifetime, GENERATOR FUEL LEVEL If you need more help, please start a new topic with more specific details about the problem. The electrician couldn't finish the activation until I linked our new unit to the internet. In the event that you have a power outage at your home and your air-cooled generator does not automatically run, it is important to know how to clear a fault in order to start your generator.1. If the fuel filter is clogged, the generator cant get a steady supply of fuel. If the alternator isnt sending enough power to the voltage regulator, it doesnt matter if the voltage regulator is working properly. You probably need to replace the fuel filter, since the filter is probably clogged with the same residue that clogged the carburetor. Confirm the generator MLCB (generator disconnect) is OFF (OPEN). I was very impressed how clean looking the unit looked at here completion of the project. Thats generally the cause of fuel around the fuel tank cap. 5 Year Limited Warranty for automatic standby generators. The peace of mind when storms are rolling through is amazing. Install was smooth and hassle free. However, the most common problems are simple enough that most RV owners can troubleshoot and repair them themselves. When the generator is dying, it starts but wont continue running. Refer to the owner's manual for routine maintenance procedures and schedules. The first question you should ask yourself is where you intend to use the pressurewasherat home or at work. #GENERAC #GENERATOR #STANDBYGENERATOR This is a video that will show you how to change the battery and reset your settings in a Generac standby generator. Generac's G-Force Engine is a purpose-built, pressure-lubricated engine capable of handling the rigors of generator use, resulting in power that's more reliable and requires less routine maintenance than any competitive engine. A pumps performance is determined by many factors such as atmospheric pressure (how high the pump is above sea level) resistance from hoses, etc. If the unit will not start in AUTO when there is utility loss, clear the alarm by pressing the ENTER button twice, then press AUTO. Kits come with all parts necessary to maintenance your portable or home standby generator. Starting with Tina in the office and Steve getting a timely quote to Steve Jr. and his partner on the install. When this step is completed, you are now able to monitor your generator from anywhere! When your home standby is displaying this error, the first thing to check is your oil level. Installers were very easy to work and eager to satisfy our location requirements. The recoil starter connects with the crankshaft to turn over the engine. You cant risk a major failure that spews fuel everywhere in a hot engine. They are engineered to run for the long periods of time required during a severe power outage or on a job site. This video explains how and why. It can also rust. During your consultation, you will receive the personalized attention and detailed evaluation you need to find a solution that works for your need. Watch this short video to learn how. You dont want fumes from a leaking fuel tank building up around a generator. Westinghouse Dual Fuel Portable - Best for Versatility. Visit generac.ordertree.com to order maintenance items. If the circuit isnt connected, then the alternator isnt sending enough power downstream or isnt sending any at all. Vertical Suction Lift is how far up the pump can be from the top of the water. Quiet-Test Self-Test Mode runs at a lower RPM for a five or twelve minute test, making generators significantly quieter than other brands while consuming less fuel. 10kW - 16 Circuit Switch WiFi-Enabled - 7172, Request Service for Home Standby Generators, Industrial Generator Heat Rate Calculator, Career Opportunities with Generac Dealers, Find the Right Size Generator for Your Home, 10kW - 16 Circuit Switch WiFi-Enabled - 7172 Reviews - page 2, Prior to providing a review, refer to a products documentation to ensure that unit is being used and maintained properly, Alluding to issues incurred in the wake of negligent maintenance or improper use will void review submissions, Focus on your experience with the product and its features, Provide details about why you liked or disliked a product, Reviews submitted for products other than those listed will be rejected immediately, Any product reviews referencing independent authorized dealers, service providers, or retailers by name will NOT be posted. 2020 GUARDIAN 18KW GENERATOR FEATURES AND BENEFITS Provides essential circuit power protection for your home, ensuring the necessities remain powered during an outage or up to whole house coverage when paired with one of Generac's load- shedding switches. If you see fresh fuel around it, replace it, especially if you see the leak as the generator is running or soon after it is turned off. If the recoil starter isnt working properly, it may not engage the crankshaft and turn over the engine. Thanks to Steve and all his crew. Transfer Switch, Installation, Taxes and Shipping Not Included. The carburetor like the fuel tank is a large container for fuel. If you dont have someone youre working with, Generac offers a Free In-Home Assessment with a local professional. If, however, you plan on scrubbing mold and mildew off concrete, or prepping a house for painting, you should consider a unit with a higher pressure. Chat With a Customer Service Representative. Since 1959, Generac has been designing and manufacturing backup power generators for residential, commercial and industrial applications. Fuel tanks can leak. Instead, contact us directly. On the other hand, the on-off switch can break and keep the generator in an off position though youre trying to turn it on. - YouTube 0:00 / 21:07 Running and Load-Testing the Generac Generator. They will evaluate your specific needs and make a recommendation that fits your budget. The options below will help you understand how the entire process works, what your financing options are, and how to choose the right backup power solution. The local authorized dealer was easy to deal with and the staff knows the product line well. Oil should be changed after the first 20-30hours of operation and every 100 hours of run time thereafter. Looking for more? If the unit was running and shuts down, attempting to restart, clear the alarm by pressing the ENTER button twice, then press AUTO. During your consultation you will receive the personalized attention and detailed evaluation you need to find a solution that works for your need. With detailed insights to your generator's information they can provide protective service and maintenance to improve the longevity of your generator investment, whether you are home or away. This code usually displays when the controller detects high RPM. Once youve verified it isnt any of the spark plugs, you can move on to the ignition coil.