fleck 5600sxt downflow

Please type an address. Put the new timer on top of the valve. Location is disabled by your browser. Position the valve to the brine/slow rinse position. If that works then the turbine is jammed and needs to be cleared. Fleck 5600 Electromechanical Softener Meter. Pull the resin tank away from the plumbing connections. Day of the Week Control, This control regenerates the system on a weekly schedule. Once the BD cycle starts counting down, immerse the end of the brine line in a clear glass of water. There are two types of water softenersavailable to help homeowners with their hard water problems: downflow and upflow technology. If the motor is running fine and the other gears are intact but the system is not cycling correctly this may solve the issue. Excerpts: Copyright 2020 FleckSystems.com All rights reserved. No dealers found. We also provide an ARTICLE INDEX for this topic, or you can try the page top or bottom SEARCH BOX as a quick way to find information you need. All Rights Reserved. 10 lbs. When Copyright 2023 Grid Sub | Fuzion BlogbyAscendoor | Powered by WordPress. In some cases, it may need to be cleaned or replaced, if there is suction at the control valve but no brine is being drawn in. The brine valve cam will hold the valve in this position to fill the brine tank for the regeneration. Printable installation instructions for backwashing systems with the Fleck 2510, 2510SXT, 5600, and 5600SXT control heads, including ASM and AdEdge arsenic systems, carbon tanks, iron filters, ph tanks, and sediment tanks, are available below. On 2020-10-17 - by (mod) - Structural ch20001 water softener? by Inspectapedia Com Moderator, @Melanie, Cabinet Softeners Fleck 5600SXT Meter Water Softener, Low-Profile Cabinet - 40,000 Grain Capacity. This is necessary because incoming water is always pressing down on the resinand eventually this compacts it with the downflow technology. IN STOCK. B2- Second Backwash: Set this to 6 minutes. Manual operation, dP triggered regeneration, interlocking, series and remote start regeneration configurations are available upon request. Our various water filtration systems offer whole-home and point-of-use applications that work to provide the best, quality water for your home. Control Type (Display Code CT): Set to Fd. 11. The level should be about 2-3 inches above the water level. This can create a situation where the line water pressure isn't sufficient to push the water up high enough. Clean Water Made Easy www.cleanwaterstore.com Fleck 5600-SXT Softener Installation & Start-Up Guide NOTE: We have not sold the Fleck 5600-SXT Softeners since 2014. Press the Extra Cycle button to go to the next step. The backwash takes 8 minutes, after which the Fleck 5600-SXT will begin to suck up the brine solution from the brine tank. Fleck water softeners appeared on the scene, they represented a new savings in water and salt consumption over softeners that existed 50 years ago. Press Extra Cycle button to continue. Fleck 5600 SXT Cabinet Style On Demand Water Softener. The The 2850 valve body is offered in the classic mechanical design for rugged construction and simple operation, as well as in the 2850SXT Electronic Programmable style for an extended range of settings and options capabilities. Using a flat screwdriver, unscrew (5) and remove the controller (4). Fleck Water Softener How to and Troubleshooting Guide, Whirlpool Water Softener How-to and Troubleshooting Guide, Common Pressure Washer Problems and How to Fix Them, Culligan Water Softener How to and Troubleshooting Guide, Insinkerator Hot Water Dispenser How-to & Troubleshooting Guide, Alexapure Water Filter Troubleshooting & How to Guide. Downflow single backwash Fltr Filter dF2b Downflow double backwash UFbd . Posted by Discount Water Softeners on Dec 7th 2018. Flecks 2850 valve is ideal for commercial filters and water softeners up to 24 to 30 diameter tank size. Using the wrong salt might form a form a bridge that prevents water from being effectively treated. Softener with 0.75 cubic feet of resin-Set CAPACITY (C) to 15,000 grains, Softener with 1.0 cubic feet of resin- Set CAPACITY (C) to 20,000 grains, Softener with 1.25 cubic feet of resin- Set CAPACITY (C) to 25,000 grains, Softener with 1.5 cubic feet of resin- Set CAPACITY (C) to 30,000 grains, Softener with 2.0 cubic feet of resin- Set CAPACITY (C) to 40,000 grains, Softener with 2.5 cubic feet of resin- Set CAPACITY (C) to 50,000 grains, Softener with 3.0 cubic feet of resin- Set CAPACITY (C) to 60,000 grains, Softener with 0.75 cubic feet of resin- Set Brine Fill (BF) to 3 minutes, Softener with 1.0 cubic feet of resin- Set Brine Fill (BF) to 4 minutes, Softener with 1.25 cubic feet of resin- Set Brine Fill (BF) to 5 minutes, Softener with 1.5 cubic feet of resin- Set Brine Fill (BF) to 6 minutes, Softener with 2.0 cubic feet of resin- Set Brine Fill (BF) to 8 minutes, Softener with 2.5 cubic feet of resin- Set Brine Fill (BF) to 10 minutes, Softener with 3.0 cubic feet of resin- Set Brine Fill (BF) to 12 minutes, Softener with 0.75 cubic feet of resin- Set Brine Fill (BF) to 6 minutes, Softener with 1.0 cubic feet of resin- Set Brine Fill (BF) to 8 minutes, Softener with 1.25 cubic feet of resin- Set Brine Fill (BF) to 10 minutes, Softener with 1.5 cubic feet of resin- Set Brine Fill (BF) to 12 minutes, Softener with 2.0 cubic feet of resin- Set Brine Fill (BF) to 16 minutes, Softener with 2.5 cubic feet of resin- Set Brine Fill (BF) to 20 minutes, Softener with 3.0 cubic feet of resin- Set Brine Fill (BF) to 24 minutes, Softener with 0.75 cubic feet of resin-Set CAPACITY (C) to 18,000 grains, Softener with 1.0 cubic feet of resin- Set CAPACITY (C) to 25,000 grains, Softener with 1.25 cubic feet of resin- Set CAPACITY (C) to 31,000 grains, Softener with 1.5 cubic feet of resin- Set CAPACITY (C) to 35,000 grains, Softener with 2.0 cubic feet of resin- Set CAPACITY (C) to 50,000 grains, Softener with 2.5 cubic feet of resin- Set CAPACITY (C) to 62,000 grains, Softener with 3.0 cubic feet of resin- Set CAPACITY (C) to 75,000 grains, Softener with 0.75 cubic feet of resin- Set Brine Fill (BF) to 5 minutes, Softener with 1.0 cubic feet of resin- Set Brine Fill (BF) to 6 minutes, Softener with 1.25 cubic feet of resin- Set Brine Fill (BF) to 8 minutes, Softener with 1.5 cubic feet of resin- Set Brine Fill (BF) to 9 minutes, Softener with 2.0 cubic feet of resin- Set Brine Fill (BF) to 12 minutes, Softener with 2.5 cubic feet of resin- Set Brine Fill (BF) to 15 minutes, Softener with 3.0 cubic feet of resin- Set Brine Fill (BF) to 18 minutes, Softener with 0.75 cubic feet of resin- Set Brine Fill (BF) to 10 minutes, Softener with 1.0 cubic feet of resin- Set Brine Fill (BF) to 12 minutes, Softener with 1.25 cubic feet of resin- Set Brine Fill (BF) to 16 minutes, Softener with 1.5 cubic feet of resin- Set Brine Fill (BF) to 18 minutes, Softener with 2.0 cubic feet of resin- Set Brine Fill (BF) to 24 minutes, Softener with 2.5 cubic feet of resin- Set Brine Fill (BF) to 30 minutes, Softener with 3.0 cubic feet of resin- Set Brine Fill (BF) to 36 minutes. Their hot water dispensers connect to the kitchen sink, Even though most RV, Tiny homes, and camper dwellers are shifting towards cassette and composting toilets, some still prefer the, Alexapure Water filter is the ultimate solution for all your water filtration needs. After the backwash stage, salt brine is automatically drawn in from the brine tank and slowly rinses through the softening resin for 1 hour, which allows the hardness minerals to be swapped out with harmless potassium or sodium ions. Press the Extra Cycle button t accept the setting and move to the next parameter. To replace timer on a Fleck 5600 follow the steps below: If there is no flow when you have some faucets open the meter turbine is mostly likely jammed. Place the softener tank where you want to install the unit. Remove the brine tank tubing where it enters the units control valve. Your water softener may not work properly if the system regenerates while you are using the water. You may need to repeat this step. $29.95. I don't assume that a short-cycling well pump is due to the water softener; use the on page search box to see the diagnostics for SHORT CYCLING WELL PUMP. The master reset is now complete. You will need to program the Softener now to your specifications and you will need to reset the clock. . These flow rates can also be affected slightly by the installation of add-on filters. Downflow or upflow regeneration cycles. Applied Membranes, Inc. is committed to customer service that exceeds your expectations. Turn the manual regeneration knob slowly in a clockwise direction until the program micro switch lifts on top of the first set of pins. Position the valve to the start of the brine tank fill cycle. Direct links to free, download-able water softener manuals or water conditioner manuals for Pentair / Pentex water softener brands & models. Select the correct installation or operation & repair manual for your Pentair Pentex water softener brand and model to be sure that you have exactly the right instructions for installing, maintaining, or troubleshooting your water conditioner. Then return the control to the In Service position. cycle on days that have been set to on at the specified Make sure that the salt dosage is set as recommended. 2 JE11 Fleck 5600SXT Downflow. Manually dial the various regeneration positions by turning the knob on the front of the control until the indicator shows the softener is in the desired position. Make sure you don't lose any of the small pieces of the connector as you disconnect the line. Homeowners don't have to reset or reprogram the time on this model in the event of a power outage. It is essential to maintain an optimum level of salt for the proper functioning of your water softener. 40,000 Grains: 7.5 lbs. A family of 4with a Fleck softener uses 912 pounds of salt per year, at a rate of 76 pounds of salt each month. If a grid is not used, fill to the top of the air check in the salt tank. To set the time of day, press red time set button and turn 24-hour gear until present time of day is at time of day. Repair and replacement parts at affordable prices. You may run the drain from twin tank units through a common line. It is also damaging to all your appliances. Check the brine in the brine tank and make sure there is enough. Moving clockwise from red pointer, extend or retract fingers to obtain the generation schedule. JavaScript seems to be disabled in your browser. On well water install the carbon filter after the water softener for . Pentair 5600SXT SOFTENER SYSTEM OPERATOR'S MANUAL For more than 40 years, Pentair has been the quality choice for water treatment professionals due to our strong, reliable brands and product lines including: GE, Fleck, Pentek, Autotrol, Everpure, Wellmate and more. Cabinet Softeners Fleck 5600SXT Meter Water Softener, Low-Profile Cabinet - 32,000 Grain Capacity. . Press Extra Cycle button to go to the next step. ABCWaters 5600SXT Fleck Water Softener 2. If there is just a shut-off valve near the inlet, close it. Resins Grains x 75% divided by Hardness = Net Gallons, Fleck 5600 Troubleshooting Brine Suction Failure, How To Set Econominder Program Meter Wheel, Sears,North Star, Whirlpool, GE Smartwater, Mortons, Removing the 155 or 255 Upper Valve Body Module, Things We Need to Know before we can provide Recommendations, CANADA - Does Softenerparts.com ship to Canada, Rebuilding Fleck 5600 Stuck or Leaking Valve / Timer Problem, 1/2" male thread x 1/2" Barbed, Drain Fitting, 5600 Rebuild Kit Pistons and Seals Softener, Adapter Coupling - One complete with clips 19228-01, Backwash Filter Piston and Seals for 5600 Backwash ONLY Valves, Brine Fitting Nut Ferrule Insert Kit 60900-38 10329 10332 10330 12767, Brine Line Flow Control .50 BLFC Button Flow Washer, Brine Line Flow Control Button Retainer - 13245, Brine Safety Shut Off Valve 3/8" 2310 ( 60014 ), Brine Valve Plug 13857 - New Part #40947-02, By Pass O-Ring Kit for Plastic Fleck - 60049, By Pass Tool for Plastic Pentiar Fleck Autotrol, By Pass Valve Plastic Fleck - 60049 Rainsoft 17557, CLIP for Spring Retainer Meter Cable Fleck 14253, Clutch for Drive Pinion Program Wheel 13831, Cover 5600 # 6022501 or 13753-02 STD Timer, Cover Back For Fleck 5600 - 13229 - New #40338, Cycle Actuator Gear Meter 5600 and 3210 - 13802, Ferrule plastic Delrin Sleeve (3/8 Tube) PN 10330 JPF375, Filter Kit Pistons and Seals for 5600 IRON FILTERS, Gear - 12 Midnight 24 Hour Wheel Assembly 19205, Gear - 2 a.m. 24 Hour Wheel Assembly 19205-1, Harness assembly flow meter 16.9" Fleck SE SXT 19791-01, Harness assembly sensor cable 8" for 5600 SE SXT or HD-SMM, Housing - "L" Bracket Fleck 5600 12 Day Version 15494-03, Housing - METERED "L" Bracket Fleck 5600 Econominder, Housing w/pin Fleck 5600 13162010 FL14448-000, Idler Pinion Gear 5600 and 3200 - part 13018, Injector Cover 5600 and 9000,9100 PN 13166, Injector Drain Assembly Fleck 5600 60084-0101, Injector Nozzle and Throat Sets Fleck Valves, Insert Brass for 3/8 tube PN 10332 JBI375, Label - Silver for Front Knob 5600 PN 14207, Manual for Fleck Model 5600 and 5600 Econominder Valve, Meter Cable Drive Pinion Program Wheel 13830, Meter Upgrade Kit - Convert Day Timer 5600 and HS-STC, Motor - Timer Fleck 120V 60Hz 1/30rpm 18743-2 old 13400, B13400,13944, Motor - Timer Fleck 24 V 60 hz 1/30 rpm 19659-1, O-ring - Adapter Uniflex Cuno MacClean ORG-234, O-ring 13/16" Distributor older Fleck 1500, 2500, 5600, O-ring Drain Fleck 5600 12638 - Injector Clack V3171, O-ring Injector Cover 5600, 9000, 9100 - Fleck part 13303, O-ring Injector For 5600 - Fleck part 13301, O-ring kit 13303, 13302,12638, 2 of 13301, Fleck 5600 Injector Module, Piston Assembly Fleck 5600 Low Water - 60102-20, Piston Main Assembly 5600 Rapid Rinse 60102-52, Power Head - 5600 Metered Standard - FL56M-PH, Power Head - Fleck 5600 12 Day 120 volt FL56T-PH, Power Head - Metered Standard - 427000-PH, Power Head 5600 "L" 12 Day 120 volt 60353-10 62090-04, Power Head 5600 "L" Backwash Midnight 120 Volt, Power Head Conversion Kit - Digital Backwash HD-FTCPWHD, Program Wheel 35 Day Timer SPECIAL 60405-16, Screw 13296 Back Cover and Component Mounting, Screw Hold Down Retainer Metal Plate 5600 12112, Screw use with Front Knob For 5600 Fleck - PN 15151, Screw used with Fleck Adapter Clip pn 13314, Seals and Spacers Kit chloramine resistant 559PE PN 60125-15, Seals and Spacers Kit Fleck 5600 and 9000 60125, Silicone 1 Gram Tube Lubricant for Orings, Skipper Wheel 12 Day Fleck 5600 and 3200 Timers, Skipper Wheel 7 Day Fleck 5600 and 3200 Timers 14860, Skipper Wheel Ring Fleck 5600 and 3200 Timers 13864, Spring Detent Main Gear 5600 - newer since 2009 - PN 19080, Timer Circuit Board 5600SE SXT Fleck 60652 42099 40283 61672-0201, TOOL to remove DLFC Retainer Fleck- 13759, Transformer D-TRANS 24 volt 60 Hz AC Hankscraft, Transformer Fleck Electronic 24 volt 19674 44147, Transformer Fleck Electronic 24 volt 50 Hz 41475, Turbine Meter Assembly 3/4 Electronic 19797 no clips, Turbine Meter Assembly 3/4 Electronic 60626 FL60626, Valve Body Lower Section - Fleck 5600 Softener Valve, Valve position dial, 14176 - standard Fleck 5600, Video Fleck 5600 Service and Operation Training DVD, Washer - Fleck 5600 at Main Gear and Piston 13363, Yoke 3/4" Quick Connect Fleck PN 61700 FL56-07QC, Yoke 3/4" Stainless Steel Fleck - 13708 41027-01. InspectAPedia tolerates no conflicts of interest. Softeners, Whole Home Filters, Reverse Osmosis, and More. Make sure the unit is level and on a firm base. Start by unplugging the electrical cord from the outlet. Your black filter tank base is not glued to the bottom of your tank. Insinkerator series by Emerson is renowned for its quality water systems. Pentair plc is a public trading company on the New York Stock Exchange under the symbol PNR. In summary, it means that with Fleck's outdated downflow technology, you will use 75 percent more salt than you would with an upflow system and 64 percent more water than today's high efficiency upflow softeners do. Put the control in the Backwash position momentarily to relieve water pressure in the softener. To fix this, clean the drain line flow control. This accumulation of deposits leads to cloggingand corrosion in your plumbing system, which reduces its effectiveness and shortens its life. The next day it went to 838 gallons and the pump stopped cycling. Main Gear & Shaft for Fleck 5600SXT (Part 42933) Main gear & shaft for downflow digital Fleck valves - 5600SE, 5600SXT 6600, 6700. Performing a master reset of the control boards on your Fleck 5600SXT may be necessary in some situations, like when it has issues that dont seem to go away from trying other troubleshooting techniques. Otherwise, the meter may as well be faulty and needing to be replaced. Their products are also reliable, delivering all the benefits you seek from a water softener. The capacity (gallons) arrow denotes remaining gallons exclusive of fixed reserve. Plug cable into the meter cover. Valves shown 110v/60Hz (SXT Valves are 24v/60Hz with 110v transformer); other voltages available. Change the setting using the Up or Down arrows. This situation can also be created if the softener drain line is routed too many vertical feet above the softener. With automatic regeneration and backwash cycles within the water softener systems and media filters, consistent performance is guaranteed. Make sure that the floor is clean beneath the salt storage tank, and that it is level. During the cold weather, the installer should warm the valve to room temperature before operating. Manually index the control to the Brine Draw position and allow the control to draw water from the brine tank until it stops. Press the Extra Cycle button. If the water level in the glass goes down, then the issue with the water softener is being caused by the safety float. Position the valve to the rapid rinse position. You can rotate the control knob just to be certain. PENTAIR WATER SOFTENER MANUALS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice. Cam Cycle Black Downflow Fleck 5600SE, 6600 17438. If it is sucking strongly, check the brine tank float inside the brine well and make sure there are no rubber bands around it, and that there are no obstructions. Ultraviolet (UV) Water Disinfection Systems, Agriculture, Horticulture, and Landscaping, Disaster Relief and Mobile Water Treatment, Microelectronics and Semiconductor Rinse Water, Hospitality - Resorts, Hotels, Restaurants, Fleck Control Valves for Water Softeners and Media Filters, Mineral Tanks for Water Softeners and Media Filters, Tank Adapters & Tank Accessories for Water Softeners & Media Filters, AMI Softeners and Media Filters Using Fleck Valves, Water Softener and Media Filtration Products, Solid lead-free brass body for long life and durability, Excellent service ow rates (51 GPM continuous, 66 GPM peak), Backwash capacity handles tanks up to 30" diameter, Mechanical 2850 Control Valves offer rugged, simple mechanical design which is easy to use. Water pressure will automatically build up in the softener. To change the setting to the desired setting, use the Up or Down arrows. So if your softener was working fine, but not it's not, it likely isn't because of the vertical height of the drain line. (2 pages) Water Dispenser Pentair 5600SXT Series Operator's Manual. Backwash capacity handles tanks up to 12" diameter for softener applications, 10" for filter applications. Whether its an undersink system or whole-house water softener, you can rest assured that our rigorously tested products stand up to Water Quality Association (WQA) and NSF International standards to remove impurities and provide clean, crisp-tasting water every time. $15.50. A faulty or clogged valve may also hinder the units functionality. This tube will often have a lid on it. Also, check the state of the salt. System #4: 1 Tank, 1 Meter, Immediate, or Delayed Regeneration, D. System #5: 2-5 Tanks, Interlock Mechanical, Meter per unit for Mechanical and Electronic, E. System #6: 2-5 Tanks, 1 Meter, Series Regeneration, Mechanical, 2-4 Tanks, 1 Meter, Series Regeneration, Electronic. These valves are a vailable in the spectrum of single tank units to multi-valve systems which deliver more than 1,000 gallons of treated water per minute. Number of Tanks (N): Set to 1, as this is a single tank system. FLECK 5600SXT DOWNFLOW SERVICE MANUAL www.pentairaqua.com CALIFORNIA PROPOSITION 65 WARNING WARNING: This product contains chemicals known to the State of California to cause cancer or birth defects or other reproductive harm. DOWNFLOW; 24,000 Grains: 3 lbs. What this means is that the household water is not flowing through the media tank and will not be softened. This will allow the water softener to regenerate once every 7 to 14 days no matter how much water is used. Add To Cart Add to Cart. A master reset restores the original factory settings. $873.00 . 48,000 Grains: 9 lbs. Here is a comprehensive guide with common Fleck water softener issues that you can use: In the softener, water enters the top of the tank and flows down through the media and up the distributor tube. (29 pages) Water Dispenser Pentair Fleck Econominder 5600 Troubleshooting Manual. As long as there is 20 minutes or more remaining, the softener should now be able to remove all of the water from the brine tank. A minimum of 30 PSI is recommended but it works better if there is 40-50 minimum PSI. Slide tabs on skipper wheel outward to expose trip fingers to set the days that regeneration is to occur. Fleck valves are also available in metered options for on-demand regeneration based on the volume of water that has been used. Pentair & Pentex Water Softener Operating & Maintenance Manuals & Guides. 64,000 Grains: 12 lbs. and performance for water softener units. For prompt, courteous and reliable service, contact us today! The injector screen could be plugged. If your water softener has stopped working, check to make sure the voltage transformer of the conditioner is installed correctly, plugged in, and working. You have now completed setting the programming. Fleck water softeners use a simple system, making them quick and easy to assemble and install. This will allow for enough water to be added to the tank before shutting the brine fill cycle. Sometimes if the brine tank is not filling adequately, it may be as a result of the float assembly in the tank being set too low. The store will not work correctly in the case when cookies are disabled. +1 (714) 432-9996, Reverse osmosis & water treatment systems. Safety Factor (SF): Set this to 10. All you need to do now is set the clock to the right time of day by holding the Up or Down arrow. Position the valve to backwash. call Fleck 5600SXT Electronic Meter; Sort by. To fix it, remove the safety float and do the following: Once that's done, put the safety float back in, re-attach the brine line (make sure this is done well, but not overtightened or the plastic fitting can crack). Address2450 Business Park Dr.Vista, CA 92081-8847 Get Directions, Toll Free1.800.321.9321Local760.727.3711Contact Us. Manually cycle the control valve to make sure it is working properly. Current Day of the Week. 1. This lifts and expands the softening media, and removes any particles trapped in the media. If you can find any numbers or data on a data tag such as is often on the side, back, or interior of the control we can usually identify the manufacturer, even if all that we have is a patent no. Display Format (Display Code DF): Set display to GAL (U.S. Gallons), or change to Liters or Cubic Meter if outside the U.S. Press the Extra Cycle button to proceed to the next step. The serial on the back says 21681 but that hasn't yielded any results. Other backwash flows are available (max. JOB SPECIFICATION SHEET Job Number: ______________________________________________ Page 22: Service Instructions Make sure control valve is returned to the In Service position. Copyright 2021 Softenerparts.com. Make sure water goes into the brine tank at the desired rate. During backwash, the flow of the water is reversed and water flows down the distributor tube and up through the media. Replacing the controller Operation Using a Philips screwdriver, unscrew (1) and remove the cover (2) paying attention for the wire. Turn on the water to the house and run the water in the house for a few minutes after the regeneration process is complete. Check this too: Common Pressure Washer Problems and How to Fix Them. Undersink & Countertop Filtration Systems, Residential Softening & Filtration Valves, Recreational Vehicle Plumbing Accessories, Turf Management & Pest Control Accessories, Commercial Filtration Solutions Customer Service, Water Supply & Disposal Pro Support Contact Us, Pentair VT 5600SXT Softener System Manual, Pentair Medical Carrier Transparency Reports, Do Not Sell or Share My Personal Information - CA Residents Only, SYSTEM, 09X48, 1.0CF, 11K PENTAIR BRANDED VT-11-01, SYSTEM, 10X54, 1.5CF, 17K PENTAIR BRANDED VT-17-01, SYSTEM, 12X52, 2.0CF, 23K PENTAIR BRANDED VT-23-01, Increases plumbing and water appliance life, and improves theeffectiveness of detergents for cleaner, brighter wash, Reduces iron-staining, scale build-up, soap film, and water spots (on pots, pans, glassware, sinks, and tubs, Three sizes available to meet every customers needs - 1.0 ft3, 1.5 ft3, 2.0 ft3, High efficiency 5600 SXT Valve saves water and salt by monitoring actual water usage, Trusted and durable Pentair components, assembled in the USA. Continuous flow rate of 20 GPM. Lubricate the distributor o-ring seal and tank o-ring seal. CD in the upper left hand corner of the screen. Replace the timer mounting screws and then replace the screw and washer at the drive yoke. Do the solder joints near the drain before connecting the Drain Line Flow Control (DLFC). Attach two clips and screws at the bypass valve or yoke. Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the. BF- Brine Fill: Set this to 12 minutes, 20 minutes, 26 minutes, or 32 minutes for 32K, 48K, 64K, or 80K grain softeners respectively. Note that the meter part of the module must be assembled at valve outlet. $829.00. Please try another location. To fix this, you will need to replace the screen. Open a cold soft water tap nearby and let run a few minutes or until the system is free from foreign material that may have resulted from installation. The Genesis Upflow, high efficiency, on demand, metered, digital water softener has a 30 percent reserve of positively charged resin from the previous regeneration. Job Number: ___________________________________________________, Model Number: _________________________________________________, Water Hardness: _______________________________________ ppm or gpg, Capacity Per Unit: _______________________________________________, Mineral Tank Size: ______________ Diameter: ________ Height: _________, Salt Setting per Regeneration: _____________________________________, A. If so, you may need to clean or replace the injectors. Check to make sure there is enough pressure. Fleck 2850 Electronic Control Valve Front, Fleck 2850 Electronic Control Valve Without Cover. in salt. DuraWater Fleck 5600SXT Water Softener 4. The draw line flow control could be plugged. The Fleck 5600 timered water softener is set to run its regeneration on set days at a certain time, regardless of the volume of water usage. Do not add salt at the brine tank at this time. If there is no dimensional drawing, cut the distributor tube flush with the top of the tank. This causes pressure loss and the injector not to work properly. Manually index the control to the Backwash position and allow water to flow at the drain for 3-4 minutes. Be sure the injector is drawing in the brine: This is another common problem that occurs if you do not have enough backwash flow rate to clean the water softener properly. Both water supplies may have contaminants that need to be dealt with prior to the water entering the plumbing system. ADD TO CART. We recommend you contact Amazon or whoever you purchased it from for support. Be sure to shut off any bypass line. Check to make sure that the brine tank does not have water after this cycle. Close the water tap once clean. Thus, the effectiveness of the softeneris weakened. Day Override (DO): Set this to 7 to 14. Turn on the main water supply. Genesis 2 Premier Water Softener 3. Fleck SXT controls provide easy, step-by-step programming at the touch of a button. * This is a both a one cubic water softener and a one cubic foot upflow carbon filter. When water flow stops, slowly open a cold water tap nearby and let run until the air is purged from the unit. If your softener brine line isn't able to create suction, it's almost always caused by a clogged injector. If possible increase your water pressure to the softener from your well pump and see if the injector works when you slightly increase the pressure. Start regeneration cycle manually if water is hard. Above: a multi-tank controller from Pentair, the Pentair Logix 764 control head, Also see more manuals that work for Pentair listed under, Also see these manuals for these control heads that are used on some Pentair and Fleck and other water softners, On 2021-12-19 Always allow the motor to stop before moving to the next set of pins or spaces. How Much Water Should Be In My Water Softener Brine Tank Posted on 23 Dec 16:06, Supply Chain / Covid-19 Updates Posted on 23 Mar 16:26, How To Troubleshoot & Fix a Fleck 5600SXT Softener Posted on 20 Jul 11:34, How Much Water Should Be In My Water Softener Brine Tank, How To Troubleshoot & Fix a Fleck 5600SXT Softener, Your softener won't regenerate properly and your water will be hard, Your brine tank will fill with water over time, until the safety float is engaged, the softener drain line is kinked, blocked, or frozen, In the even that too much water is added to the brine tank, the safety float will shut off the water flow to the brine tank avoiding a flood, The safety float also acts as the pickup tube for the brine solution.

Squier Contemporary Jaguar Switching, Lorac Alter Ego Lip Gloss, Socialite, Invalid Request Provided Aws::ssm::resourcedatasync, Articles F

fleck 5600sxt downflowLeave a Reply

This site uses Akismet to reduce spam. female founder events.