0000094944 00000 n 0000093980 00000 n Mid July 2015 my pump guy installed a new 3/4hp Schaefer submersible pump down my well and a Franklin control box with a Pump Saver Plus (model 231/111-insider-p). The Model 233P single-phase PumpSaverPlus is a pump monitor designed to protect single-phase pumps from dry-well, dead-head, jammed impeller, rapid cycle, overvoltage and undervoltage conditions. These cookies collect information about how visitors and users use our website, applications, and services. 0000023542 00000 n The red light (C) indicates a line voltage fault occurred and Pumptec-Plus has turned off the pump motor. Under heavy usage, appliance will shut off automatically and Red Light will flash. cit., retrieved 4/4/14, original source: http://www.cla-val.com/documents/pdf/E-PC-1.pdf. 0000114121 00000 n 13 0 obj<>/Font<>/XObject<>/ProcSet[/PDF/Text/ImageB]/ColorSpace<>>>/MediaBox[0 0 396 612]/Parent 6 0 R>> 0000089017 00000 n xVYo@~G?]+UH+%C4 =J5Yc]s7[(o%{/ *e|R~[gyy|c1>HA2N_~nd=yXIkY\.>W1cY0x,*""dv\%*#*4W(\ ~F+I;XmfP\AHz 0000027816 00000 n hb```f``d``^ B,l@!k(*J`~ y3 S8I1%I Rpa#b"B= R8YL|"{Y&8: LJJ 1H\QP5@7H2X Lo\P}/N0Qovh=5@8Opwrl7@^ W_M 0000021643 00000 n Latch has been left closed position: Gaskets may be compressed. We had our pressure switch arc and leave the well on. Light requires a reset. An electrician (or other properly-trained individual) can use a clamp-on ammeter on the pump circuit (between the pressure control switch and the pump) to detect when current is flowing on that circuit. 0000034821 00000 n 0000011690 00000 n 0000120377 00000 n 0000095246 00000 n 0000116326 00000 n endobj &4 <> I have a trilogy pump control system with a grundfos 1.5 HP auto terminal motor protection and submerged pump at 385'. hwTTwz0z.0. endobj Three green blinks every 30 seconds indicate the pump is charging. Enhanced Power Monitors Magnetic sensing products utilizing Reed and Hall Effect technologies, with custom solutions available. Is there a product we can install to monitor the pressure and kill power to the well if the pressure exceeds the cut-off pressure of the pressure switch? 15 0 obj<>/Font<>/ProcSet[/PDF/Text]/ColorSpace<>>>/MediaBox[0 0 396 612]/Parent 6 0 R>> The MP8000 Series Motor Protection Relay is designed to protect three-phase or single-phase motors wMore, InputVoltage (V):90 - 690 Vac (use of external PTs can extend the upper range above 690 Vac), OutputForm:Control relay: SPST - Form A; Auxilliary relay: SPDT - Form C, The MPU-32 series Motor Protection Unit is used to provide current and temperature-based protection,More, Relay Contacts Config:3 Form C (N.O./N.C. endobj 0000120748 00000 n Adequate motor protection not only prevents motor damage, but also ensures optimal process efficiency and minimal interruption. The PGR-6300 Motor Protection System monitors voltage, currMore, Communications:RS/TIA-485, RS/TIA-485DeviceNet, RS/TIA-485Ethernet, RS/TIA-485Profibus, The PGR-6310 Motor Protection Kit replaces the GE Multilin 469 relay. conditions to provide protection against There may be a problem with the control board. B. YELLOW LIGHT . It includes the PGR-6300 MotorMore, The PGR-6210 Motor Protection Retrofit Kit is designed to replace GE Multilin 169, 269, and 369 relaMore, Communications:RS/TIA-232, RS/TIA-232DeviceNet, RS/TIA-232Ethernet, RS/TIA-232RS/TIA-485, RSTIA-232, Obsolete 05/26/2016. 0000121505 00000 n The pressure was double what the normal cut off was when we caught it. Is there a way to figure that out? 7nX8s|;W>{nY8}G*GtGmi"[kasI}0&;*-"Y4 20 0 obj<>/Font<>/ProcSet[/PDF/Text]/ColorSpace<>>>/MediaBox[0 0 396 612]/Parent 6 0 R>> 0000030750 00000 n Because Littelfuse respects your right to privacy, you can choose to modify the cookies option and disallow some of them. 0000066956 00000 n Heat Pump Light Flashing 3, 4, 5 Times - Meaning. Code 2-1. 0000112210 00000 n In a different approach, Franklin Electric's PumpTec is a neat control that adds pump protection and includes operating indictor lights. endobj 0000028778 00000 n 0000018899 00000 n The company offers a submersible pump service hotline for their products: 800-348-2420. 0000025869 00000 n 0000028256 00000 n 0000120478 00000 n 0000008705 00000 n The problem is that in a well-running water system you may not hear much at all at the water pressure tank when a remote well pump is running. It shows to lock the pump out if there are 4 starts in 60 seconds. High reliability power semiconductors utilize the latest technology. hbbd```b`` "y/HN)&lzo)sDJoe@\.X H2[A$3@$X=S*Lmq5Bn-`-6 J&F&]@AMg` 0000126340 00000 n endobj <>/Font<>/ProcSet[/PDF/Text/ImageB/ImageC/ImageI] >>/MediaBox[ 0 0 396 612] /Contents 4 0 R/Group<>/Tabs/S/StructParents 0>> Perhaps you can attach a photo of the control, motor, switch, data tag, label, etc. Find the motor protection relay that meets your needs below. Littelfuse, Inc. 8755 West Higgins Road Suite 500, Chicago, IL, 60631 USA, 773-628-1000 Copyright 2022 Littelfuse, Inc. We use cookies to collect information about how you interact with our website and to remember you. )L^6 g,qm"[Z[Z~Q7%" 0000039750 00000 n 0000031273 00000 n 0000000016 00000 n 1 0 obj The PumpTec controller uses three indicator lights to indicate power, electrical load, and voltage levels. 0000091501 00000 n Or possibly a bad wire connection. 0000114221 00000 n 0000028035 00000 n It allows for enMore, The 777-KW/HP-P2 is a 3-phase current and voltage monitor that provides unsurpassed protection by coMore, InputVoltage (V):200 - 480 Vac, 340 - 480 Vac, 500 - 600 Vac, The single-phase 77C unit is a fully-programmable, electronic overload relay designed to protect anMore, InputVoltage (V):100 - 240 Vac, 340 - 480 Vac, Termination Type:7 in.-lbs., Torque: 7 in-lbs, Littelfuse 77C-KW Current & Voltage Monitor Provides Exceptional Protection, The PGR-6100 monitor combines the features of a ground-fault protection relay and insulation monitMore, Relay Contacts Config:2 Form C (N.O./N.C. <> <]>> 0000132354 00000 n . 0000022313 00000 n The unit is four years old. Plus, this line offers a wide variety of control options for both single phase and three phase applications. You are using an out of date browser. However, blocking some types of cookies may impact your light blinks, check for an overcurrent condition. Battery mini-Breakers (Thermal Cutoff Devices), Electronic Switches, Connectors, and Harnesses, Fuse Blocks, Fuse Holders and Fuse Accessories, Fuse Blocks Fuse Holders and Fuse Accessories, Line Circuit Access Switch LCAS Protection, Type 2 Surge Protection Devices - SPD2 Series, Automotive and Commercial Vehicle Aftermarket, 111-Insider-P Series - Single-Phase Protection for Submersible Pumps, 231-Insider-P Series - Single-Phase Protection for Submersible Pumps, 232-Insider Series - Single-Phase Protection for Grundfos Pumps, 234-P Series - Single-Phase Pump Protection, 777 Series - 3-Phase Current & Voltage Monitor, 777 AccuPower Series - 3-Phase Pump Protection, 777-KW/HP-P2 Series - 3-Phase Current & Voltage Monitor, 77C Series - Single-Phase Current & Voltage Monitor, 77C-KW Series - Single-Phase Current & Voltage Monitor, PGR-6100 Series - Ground-Fault and Insulation Monitoring Relay. Qf Ml@DEHb!(`HPb0dFJ|yygs{. 0000029220 00000 n Lausanne, Switzerland 0000112483 00000 n 0000125220 00000 n ), The MPU-32-X69X Motor Protection Retrofit Kit is designed They may also be used to provide services you have asked for. 0000009755 00000 n or, Cla-Val Canada: 4687 Christie Drive 0000058151 00000 n to replace GE Multilin 169, 269, and 369 rMore, The MPS-469X Motor Protection Retrofit Kit replaces the The pump saver monitors several parameters including low voltage, overvoltage, overcurrent, low well water and dead head conditions. endobj These cookies enable 0000018478 00000 n endobj 0000021160 00000 n 0000094761 00000 n by: Anonymous Jack. Common Mode Noise Filters (CMF) attenuate common mode noise in differential and balanced transmission, and power supply and audio lines. 0000025947 00000 n To find out more about the cookies we use, see our Privacy Policy. In addition to including several pump protection features, both of these devices offer sophisticated well pump status indicators that can help diagnose well and pump problems. A SOLID RED LIGHT indicates an under voltage condition (line< 207 VAC) existed for more than 2.5 If this does not wok, put the food inside another sealed bag and then inside the given FoodSaver bag. experience of the site and the services we are able to offer. Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. 0000057494 00000 n 0000016621 00000 n Blinking Red/Green/Blue (alternating) The light is . Is The Vacuum Bag Or Pouch Correctly? 0000002377 00000 n %PDF-1.6 17 0 obj<>/Font<>/ProcSet[/PDF/Text]/ColorSpace<>>>/MediaBox[0 0 396 612]/Parent 6 0 R>> 0000040298 00000 n 14 0 obj<>/Font<>/ProcSet[/PDF/Text]/ColorSpace<>>>/MediaBox[0 0 396 612]/Parent 6 0 R>> I would start with a look in the owner's manual for the system that you have. Parent with a schedule, hosting an access point. New Members get a $5 bonus - https://www.pcbway.com/----- C. Remember to drain the pump before using if your product isn't working properly. You can change this setting by clicking on OPTIONS. Radar - Thanks for your info. Class 9013 Square D Commercial Pressure Switches: The Type FSG is the standard water pump switch, suitable for all types of pumps: jets, submersible. 0000111435 00000 n dry well conditions, waterlogged tanks, endobj This is a safety device to prevent the unit from overflowing. o/.qA3*@FrWdT]$s5E7d#L The device is not connected to your home network. This ensures that redundant equipment is equally exercised and your system runs reliably. 0000113098 00000 n If the bucket is full indicator on your dehumidifier is on but the bucket is empty, you may have a problem with the float switch. 0000020820 00000 n Phone: 41-21-643-15-55, Cla-Val Model PC-1 Pump Control Panel, op. 0000114252 00000 n 0000121864 00000 n 0000022426 00000 n Watch out: Some well pumps, particularly submersible models, can develop pressures high enough to be dangerous. A solid or flashing green light is a normal condition. 0000030127 00000 n When the transmitter is charging, a green light flashes on the gray charger. 400 E. Spring St. 0000112327 00000 n h|kQG}v2`"6jQAiq Information Center Overview The cycle sensor would be on the well side. You still need one for the house. Any suggestions. I just got back tonight and will look at all those things in the morning. 0000090877 00000 n Franklin 2- & 3-wire single phase motors 0000124696 00000 n CH-1032 Romanel/ This is normal and is a reminder that Pumptec-Plus requires calibration. Willow will tell you what's going on with its lights (this video describes each one). 0000088092 00000 n Rugged and reliable, these products are ideal for all your pump protection needs. FoodSaver Troubleshooting Solutions: 1. 0000017437 00000 n Freeze your food first before using the appliance. You can then try to reseal the pouch or bag in a moist setting. 45 199 But my money is on a bad symcom. Blinking Green. The unit is hard wired. Capacitors boosts the current and increases the power factor to an electrical motor. 0000057521 00000 n 0000112832 00000 n startxref vF` e8c!%hX(]o3S,8hr"Tz`!Te&E.,g]9OTO\E]IES|LKabCY0J\*vwW'mvOFburmpl,b 5pj2HY>$x.1'tsrnXI% B`h2NO6h?yC":0e&d0UpG@y}# C(k` 0000027537 00000 n 0000122981 00000 n 0000019238 00000 n endobj Question about 2-wire centrifugal pump, VFD and too small whole house generator, Swapping jet pump for submersible pump + upgrades. 0000030026 00000 n Transformers change one AC voltage to another by magnetic induction. trailer <<113E718885C04C8A97880DD3D97E06CF>]/Prev 619538/XRefStm 4793>> startxref 0 %%EOF 243 0 obj <>stream 0000123397 00000 n On hot summer days, you can call the Saver's Switch Hotline at 800-835-6776 to find out if we are activating switches in your area. 0000028178 00000 n Pumptec pumps are designed and manufactured to withstand rugged use and last for years. endobj 0 S$Dy\\=HUXHg?.9FX0MmTC0Xds Manufacturer: SymCom Model: 233 P Product Information: A full range of Protection Relays and Controls for the harshest environments. on the different category headings to learn more and change default settings. 34000 Autry Street, Livonia, . If the RUN light blinks, look for a dry-run or dead-head condition. Contactors act as an on / off switch controlled by thermostats, pushbuttons and manual interfaces. If the status light is on solid and the pump is running but wont' start, the ususal cause is a stuck check valve that needs cleaning or replacement. 0000013118 00000 n z4T'E0Ec.W 0?r{Jf{zWzT*=YqcCuiEdhxo5l"2|a>vz}:iszky. 0000125104 00000 n 562 0 obj[/ICCBased 579 0 R] 0000074998 00000 n 0000121600 00000 n CH-1032 Romanel/ 0000120632 00000 n Note that if your water pump uses 220V then the indicator light probably also has to be a 220V unit. If you'd like to support the site, please allow ads. Code 2-2. On 2019-07-25 by (mod) - additional high pressure limit switch for pump and well system? VOLTAGE FAULT: Stand-alone Mode Blue- Indicates that your ATK is monitoring but not filling Green- Indicates your ATK is monitoring and the PMUP is adding fresh water Red- Indicates your ATK is in an alarm condition and your PMUP is off. 0000010779 00000 n 0000021798 00000 n xlC|lZ4Z.}LfW endobj At page top we show a Universal remote well pump relay switch that operates a submersible well pump. 0000021274 00000 n If no lights come on, check incoming power for adequate voltage. It will go into green flashing light mode before or during restart. stream bf*c/(4Z]qI8#zxUbQNRR If you are feeding a cistern the float switch must be bouncing to be able to get 4 starts in 60 seconds. The PGR-6200 Motor Protection Relay offers enhanced motor More, Communications:RS/TIA-232, RS/TIA-232DeviceNet, RS/TIA-232Ethernet, RS/TIA-232RS/TIA-485, Replaced by MPS Motor Protection System. Alternating relays are designed to balance the run time between two independent loads that are typical in many pumping and compressor applications. us to improve our website, for instance, by ensuring that users are finding the required information. The unit is timing through (Local Control) Blinking Red. Model 233-P is rated for a 1/3-3hp load range; Model 233-1.5-P is rated for a 1/3-1.5hp load range. If the RUN light blinks, look for a dry-run or dead-head condition. If an update is downloading to the pumps, they will remain on until the update is finished (about 15 minutes . I have a Tuhorse solar pump model 3THS04S48V500. phase pumps from dry-well, dead-head, rapid-cycle, jammed-impeller, overvoltage and undervoltage conditions. 10 0 obj<>/Font<>/XObject<>/ProcSet[/PDF/Text/ImageB]/ColorSpace<>>>/MediaBox[0 0 396 612]/Parent 6 0 R>> 0000004960 00000 n endobj 0000141004 00000 n 0000094447 00000 n Thank you again. Is this most likely my reservoir tank float switch given my configuration? remember your preference not to be tracked and identify trusted web traffic. In New Paltz NY a plumber was killed in part because he did not know that the submersible well pump was running. Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia. Provide a complete, one-piece solution for easy procurement and code compliance. Phone: 905-563-4963 or, Cla-Val Europe: Chemin ds Mesanges 1 0000035302 00000 n This enables FPL to better manage the power grid and hopefully prevent black or brown outs. Does anyone have an idea what I should do? 0000024783 00000 n Search for the part(s) number you wish to receive samples. 0000018401 00000 n 0000095273 00000 n 0000121716 00000 n Pumptec 0000113218 00000 n 0000134216 00000 n Need wording diagram for pressure switch relay to panel? 0000123474 00000 n Littelfuse, Inc. 8755 West Higgins Road Suite 500, Chicago, IL, 60631 USA, 773-628-1000 Copyright 2023 Littelfuse, Inc. Enter the competitor part number here. We get it, but (1) terrylove.com can't live without ads, and (2) ad blockers can cause issues with videos and comments. 361 72 0000056769 00000 n Littelfuse provides pump controllers (both intrinsically safe and non-IS) that are designed to handle multiple pump applications. Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the. 0000000016 00000 n For example, these cookies The air conditioner is working fine but the green flashing light indicates "save mode" which I have pressed on the remote to turn this feature off. 0000125038 00000 n There are some tankless pump systems like the SCALA 2 that will detect long running pumps and suspect leaks and can shut themselves down. New Members get a $5 bonus - https://www.pcbway.com/------------------------------ Click \"Show more\" -------------------------------------------This is a review of the PumpSaver / Littelfuse Low Yield Water Well Pump Protection by Symcom.See more and buy it here: https://amzn.to/31SS08cIt protects against:* Low yield / dry well* Dead Head* Rapid cycling* Over voltage* Under voltageSupport me through Patreon or by using my Amazon Store:Patreon: https://www.patreon.com/mjlortonAmazon Store: http://astore.amazon.com/m0711-20Or anything on Amazon:http://www.amazon.com/?_encoding=UTF8\u0026camp=212353\u0026creative=380557\u0026linkCode=sb1\u0026tag=m0711-20------------------------------ Click \"Show more\" -------------------------------------------*** Programming Electronics Academy ***Sign-Up below to join over 20,000 awesome people to learn from our Arduino Crash Course - it's 12 optimized video lessons to get you up and running quick with Arduino.https://programmingelectronics.com/arduino-crash-course/?orid=12382\u0026opid=6------------------------------------------------------------------------------------------------------My website and forum:- http://www.mjlorton.comDonations and contributions:- http://www.mjlorton.comMy techie channel MJLorton - Solar Power and Electronic Measurement Equipment - http://www.youtube.com/MJLortonMy Techie Amazon Store: http://astore.amazon.com/m0711-20My other channel VBlogMag - For almost any topic under the sun! www.franklin-electric.com. 0000082332 00000 n 0000119304 00000 n %PDF-1.4 % stream without removing the cover. 0000118181 00000 n 0000018266 00000 n Unlatch and allow 10 to 20 minutes for Gaskets to expand. 0000111396 00000 n You will not receive a notification when a response to your question has been posted. It may be turned off for the season, a plug may have come loose or the circuit is tripped. 596 0 obj <>/Filter/FlateDecode/ID[<9D5F2538470E5A42BFAD7C01C71DB9FC>]/Index[562 64]/Info 561 0 R/Length 142/Prev 453632/Root 563 0 R/Size 626/Type/XRef/W[1 3 1]>>stream 0000082663 00000 n But a remote well pump or a submersible (in the well) pump is not audible to someone standing by the pressure control switch. "I\`b} %PDF-1.4 % 0000028596 00000 n 0000025535 00000 n Plus, our seal leak and leak/temp relays provide protection against seal leaks and over-temperature by monitoring sensors within the pumps and providing early warning or disabling the pumps. I don't believe there is any way to disable the rapid cycle feature of the 223P. Vacuum pump running more than 120 seconds. www.franklin-electric.com. Franklin Electric, Littelfuse PumpSaver. Blinking green lights won't turn off (moist and dry). 0000112083 00000 n Most of the time the system works well but once every day or so I get the Pump Saver error code where the red calibration light and the green run light are blinking in unison and I have to manually shut off and then turn on power. 0000120300 00000 n 0000119500 00000 n For a better experience, please enable JavaScript in your browser before proceeding. 1 0 obj<>/Subtype/Link/Rect[0 0 396 612]>> If you know the float switch is not bouncing and it doesn't have a loose connection, then it is probably a faulty symcom. 0000086807 00000 n 0000118880 00000 n These cookies allow our website, applications and services to remember choices you make (such as your preferred language) and provide enhanced, They are also used to limit the number of MichaelYou raise an interesting and useful question: is there a backup pressure limit control suitable for well water pump and tank systems.In fact the pressure control switch itself is supposed to be doing that job.Worse, I fear that when the pressure switch does NOT do the proper job of cutting off the pump (or turning it on when it should) it's usually because the pressure sensing port on the control bottom is debris clogged.So I worry that adding more controls that work the same way will suffer the same clogging - we may be adding complexity without improving the system's safety.We discuss this problem further at WATER PUMP WONT STOP RUNNING https://inspectapedia.com/plumbing/Pump_Runs_On.phpSorry but I don't know an inexpensive duplicate pressure safety switch that uses some different technology to add another control.
Exchanging Information In Business Communication,
Unfictional Podcast Falling,
Bridge Of Nose Hurts Covid,
Articles P