Be the first to know about promotions, new products, upcoming events, and other important news. Meanwhile, spending $500 every six to 10 years on a new tank is not a terribly satisfying experience, especially it if breaks down and dumps its contents everywhere. Given his own successful experience with tankless, Carver doesnt shirk from the challenge of persuading skeptical customers. Finally a direct tankless replacement for a 40 and sometimes 50 gallon tank that can be installed in the same time as a tank type water heater is now available. Serving the needs of the one-bath household, the unit was located in a 5-foot x 8-foot laundry room with a stacked washer-and-dryer setup inside the slab-on-grade structure. Default Temperature Program Setting Options (without remote) 120, 130, 135, 140F: Production Date Range: 8/2014 - Present: Technical Specs & Installation: Min Gas Input (Btu) . All rights Retro fit of those tanks has been made EZ by our new top mount water . How do I raise the temperature above 120F? The ability to use an existing b-vent allows for a cleaner installation. These codes can diagnose problems that otherwise might remain unnoticed until unit failure, thus saving on repair and replacement costs, says Randy Oshiro, Assistant Manager of Engineering at Noritz. Brand Name: Noritz. Find local plumbers and get FREE Quotes! The Noritz EZTR40 utilizes top mounted water connections for faster and easier installation. Labor Warranty 1 Year, O-Ring - Thermistor High Temp P4 (replaced 1323709), O-Ring - High Temp P16 (replaced 3223302), O-Ring - High Temp P12.5 (replaced 3359808), C Clamp - Water Pipe 16A (Replaced 6340300), Thermistor Holding Plate (replaced ALSD088), Thermistor - Cold Water (replaced BWCD097), Thermistor -Heat Exchanger (replaced BWCD098), Gasket - Intake Air Filter Top and Bottom. Address Labor Warranty 1 Year, O-Ring - Thermistor High Temp P4 (replaced 1323709), O-Ring - High Temp P16 (replaced 3223302), O-Ring - High Temp P12.5 (replaced 3359808), C Clamp - Water Pipe 16A (Replaced 6340300), Thermistor Holding Plate (replaced ALSD088), Thermistor - Cold Water (replaced BWCD097), Thermistor -Heat Exchanger (replaced BWCD098), Gasket - Intake Air Filter Top and Bottom. The EZTR40 or NRC663-FSV. Annie Moussin designer intrieur. With experience, I believe I can cut that two-hour time frame maybe by half, he says. But the zero footprints advantage of a wall-hung tankless water heater can be every bit as compelling to a homeowner. The water heater gets the indoor air for the gas combustion through the air filter and provided slots at the front cover. Your ProCard account allows for personalized support of all your Noritz products. NORITZ AMERICA CORPORATION, a subsidiary of Noritz Japan, has corporate offices in Fountain Valley, Calif., and Atlanta, offering a full line of tankless water heaters to meet the hot water demands of residential and commercial applications. Watch the video for more. documents and warranty information. Plus, the initial cost of tankless versus tank scares many away. Since this error can be caused by scale buildup or hard water, performing a descaling procedure or using a water softener may resolve it. Instead of absorbing more precious space in an already cramped area, this solution would actually use less much less making the room both more attractive and more functional. A code 90 indicates a combustion abnormality caused by an improper mixture of air and fuel. Jason Fleming serves as marketing and customer care manager for Noritz America, based at company headquarters in Fountain Valley, Calif. The owner, who bought the home in 1998, says the units installation predates her purchase. Noritz has changed the game with the new EZTR40. Possible culprits are insufficient gas supply, a blockage in the fuel vent or debris in the fan motor. The EZTR40 model is an indoor, power-vented unit that utilizes an electric fan to blow the gases out through the 2" flexible pipe. This Noritz TechTip videio will demonstrate how to use the remote keypad to check the error code history of a Noritz Tankless. EZTR40-NG Noritz 6.6 GPM Natural Gas Residential 40 Gallon Tankless Water Heater, Hirsch Pipe & Supply, 15025 Oxnard St., Suite 100, Van Nuys, CA 91411. Looking for replacement parts for your tankless? The EZTR40 or NRC663-FSV. Services LLC Associates Program, an affiliate advertising program designed to The EZTR40 is the NRC663-FSV, which comes with EZ2FVK-1 plus Isolation valves. Noritz supports its products with a national network of skilled representatives and employees who are committed to providing the finest products and services to our communities by helping consumers live in a more comfortable, efficient and healthy lifestyle. Due to its low NOx gas emission models can be used in regions with strict laws for pollution and emission of greenhouse gases. 2023 Product Catalog EZ Series Catalog Tank vs Tankless Trifold Service Support Find a Servicer Warranty Status Returns & Claims Support Site FAQ Live Technical Support Call to speak to one of our Noritz experts at 1-866-766-7489 Hours: M-F 5am-6pm PST, Saturday and Sunday 7am-4pm PST Min. troubleshooting solutions. You will need a licensed contractor to resolve this error. Designed to replace a conventional 40-gallon tank-type water heater for two-bath residences in warm-weather climates, the new EZTR40 streamlines the tank-replacement process Technical Literature Tankless Diagram Technical Specs Warranty All Parts Ordering 95 items, 30 per page 1 2 3 4 1323709-B Noritz Tankless, including support in warm-weather climates, the new EZTR40 streamlines the tank-replacement process, Heat Exchanger Warranty (w/out Recirculation) 12 Years Narrow down your search by looking through our available parts categories. Improper circuit board settings will cause a code 73 error. 2023 Noritz America | All Rights Reserved. For a limited time, you can return to the old store here. See how Noritz helped a local brewery with their unique situation with our prefabricated rack system. This often results from scale buildup, which hampers heat-transfer efficiency and makes the unit try to compensate by burning hotter. He or she will check gas pressures, venting length, dip switches, etc. This hesitation did not last long, however, as the homeowner pondered her predicament. This error code involves a breakdown in communication between two tankless water heaters using the Quick Connect Cord. Read reviews. That slowed me down a bit, but it was not an impossible situation.. Designed to replace a conventional 40-gallon tank-type water heater for two-bath residences in warm-weather climates, the new EZTR40 streamlines the tank-replacement process Technical Literature All Parts Ordering 80 items, 30 per page 1 2 3 FDAD051 Drain Connection - 1/4" tube $7.53 JBGJ024 Contact your licensed contractor to make sure this is the case. Putting on the hard sell is a task most of us plumbers included would happily avoid. Noritz EZTR40 EZTR40NG Condensing Tankless Water Heater, 0.2 gal Capacity. Noritz EZTR40 offers a new approach in tankless water heater installation, top mount water connections, and convenient venting directly through the existing 3" and 4" B-vent. 11160 Grace Avenue However if you need a higher temperature, you can follow the steps in this video to bypass the lockout: Temperatures above that are scalding and could cause harm or injury if youre not careful. Thus, another tankless convert had been won. The EZTR40 saves you space taken up by a regular tank heater with its compact size. Find local Noritz Installers. CPN: Manufacturer: Noritz America Corp. Looking to raise your Noritz tankless water heater temperature above the default 120 degrees Fahrenheit? I took my time, making sure I did everything by the book. Familiarity, in short, will bring greater installation speed without sacrificing workmanship. The 28-year old plumber, who has worked with the tools since he was 13, came away an enthusiastic convert. Given its age, there really was little surprise when it began to leak in early February. Noritz Error Code 16 A sharp spike in outlet water temperature will cause a code 16. Carvers business focuses on helping consumers renovate their homes, which should be an ideal scenario for going tankless. Call one of our product specialists today at 1.866.766.7489 or email them at sales@noritz.com Find a Distributor EZTR40 EZTR40 BUNDLE NRC663-FSV .87 Uniform Energy Factor Minumum 15,000 to Max 120,000 BTUh 0.5 to 6.6 GPM FIND YOUR INSTALLER CURRENT LOCATION: QUINCY, WA No Results Found Accueil; Services; Ralisations; Annie Moussin; Mdias; 514-569-8476 The EZTR40 or NRC663-FSV. Changing a jumper connection or dip switch while power is supplied to the heater can trigger the problem, as can an improperly programmed circuit board. Carver used the new, Noritz EZTR40 condensing tankless water heater on a recent residential re-placement job and slashed his normal tankless installation time by roughly two-thirds. Noritz Error Code 12 A code 12 means the unit has a weak flame and that water is not being heated properly. Noritz cannot assume any responsibility for and injury or death. KENNER, LOUISIANA (MAY 2015) Persuading a homeowner to switch from tank to tankless in a water heater-replacement situation usually takes a little bit of salesmanship, admits Matt Carver, owner of MLC Plumbing Inc. in Kenner. Noritz Condensing Tankless Water Heater, Series: EZTR40, NRC663-FSV Model, 0.2 gal, 15000 to 120000 Btu/hr, 83 W, 0.5 to 6.6 gpm, 0.91 Energy Factor, 2 in Dia Vent, 120 VAC, 60 Hz, 3/4 in Water Inlet/Outlet, 1/2 in Gas, 15 to 150 psi, Natural Gas, Direct Electronic Ignition, Steel, Polyester-Coated, 18.3 in W x 27.2 in H x 9.4 in D. Please fill out the below form. To her credit, my customer was thinking about more than her immediate needs, recalls Carver, who has worked for this owner on many household plumbing projects. Noritz Tankless Gas Water Heater * The water heater has been factory set to allow a maximum temperature setting of [120 F / 50 C]. Similar to a code 11, this is caused by lack of gas or airflow. Buy a tankless water heater, and youll recoup the up-front premium in fuel-bill savings over time, and you wont have to deal with the headaches of replacement nearly as often. Available Temperature Settings (with remote), Default Temperature Setting (without remote), Default Temperature Program Setting Options (without remote), Centrotherm 2"-Flex only (Not applicable PVC venting), Vent Termination Clearances to Any Building Opening (ft), Top = 12", Front = 4", Sides = 3", Back = 0", Combustion Air Requirements - using Indoor Air, Combustion Air Requirements - using Outdoor Air, Power Consumption w/out Freeze Prevention, Tested to UL Computer Controlled Safety Standards, Durable Steel Casing with Polyester Coating, Anchoring Screws, Owners Guide, Warranty, Installation Manual, Energy Guide - Est. Fountain Valley, CA 92708, 2020 Noritz America | All Rights Reserved, Southern Climate: 2 Baths; It means that your unit is not firing up to heat the water, a situation that can be caused by insufficient gas supply, insufficient airflow or debris on the ignition plug. 1. Hours: M-F 5am-6pm PST, Saturday and Sunday 7am-4pm PST. Enter your zip code and let our sizing calculator Looking to raise your Noritz tankless water heater temperature above the default 120 degrees Fahrenheit? The EZTR40 or NRC663-FSV. Similar to a code 11, this is caused by lack of gas or airflow. Note:Professional installation and repair are recommended. Retro fit of those tanks has been made EZ by our new top mount water connections, gas line, and most of all the ability to vent directly through the existing 3" or 4" round B-Vent. Our knowledge base is designed to help answer Like other Noritz tankless water heaters, theEZTR40is a reliable and safe unit; it is equipped with several safety devices and a display window that shows the numerical error code in case of failure. Get quotes, .87 Uniform Energy Factor 11160 Grace Avenue In the meantime, the busy plumber dispatched a colleague to the home to measure the space for the drip pan that would be required. Call your licensed contractor who will likely take similar steps as outlined for code 11. At that point, Carver made his case on behalf of tankless. These water heaters can utilize both natural and propane gas, allowing usage in cabins and cottages where the natural gas is not accessible while the propane can be delivered. 2023 Noritz America | All Rights Reserved. Second, while the switch to tankless was driven by anticipated savings, it wasnt on installation labor or even monthly fuel bills, but on space in her home. Bypass the Default Noritz Temperature Lockout By default Noritz Residential units will lockout temperatures above 120F. Northern Climate: 1.5 Baths. EZTR40 has the ability, using the modulating gas valve, to operate in the power range from 15,000 to 120,000 Btu while still providing excellent energy efficiency of 0.91 (for both natural gas and propane types), which guarantees reduced energy usage and decent savings. If you need more convenience and more temperature settings, a remote controller is offered as an option. High Elevation Adjustment: Yes (Max. If the error continues, contact a licensed contractor. Bypass the Default Noritz Temperature Lockout, Clean or Change the Fan for a Pre-Mix Unit, Replacing a Circuit Board for Pre-Mix Units. UPC: 817000013097. He or she will make sure your gas valve is open, the exhaust vent is unobstructed and the ignition plug is firmly attached and free of debris. This code indicates a problem with condensate drainage.